Promotion of National Certification
Environmental Protection Concept
● YIYEN Electric Technology Co., Ltd. designs and manufactures world-leading clean technology to improve power quality, energy efficiency, operational and environmental performance. Our dynamic compensation solutions – active harmonic filters, STATCOMs, SVCs, energy storages – effectively solve your power quality problems in real time.
● The extensive experience of our team from a most varied range of applications and our strong focue on R&D provide you access to world class technology to help you solve modern power quality issues in a reliable and sustainable way.
Your Trustworthy Power Quality Solutions Provider
AHF ( Active Harmonic Filter )
SVG ( Static Var Generator )
GET FREE QUOTEAVC ( Active Voltage Conditioner )
● As a result of attention to quality and reliability, our products have been approved by TLC & CC CF. And we have attained CE, TUV, FCC, PCT, and ISO9001 certificates, with UL pending. In addition to our economical prices and customer service, it has helped our products to gain popularity and good reputation globally.
AHF ( ACTIVE HARMONIC FILTER )
Active harmonic filters (AHF) are the ultimate answer to power quality
problems caused by waveform distortions, low power factor, voltage variations, voltage fluctuations and load unbalance for a wide range of segments and applications.
AHF OPERATING PRINCIPLE
VIEW VIDEOLong-Term Cooperative Partner
Percent Satisfaction Degree
Countries Internation Trade
TYPE: 220V/ 400V / 500V/ 690V
YIY - AHF Technical Specifications
Max neutral wire current: 50A, 75A, 100A, 150A
Harmonics filtering: 2th to 50th Harmonics, the number of compensation can be selected, and the range of single compensation can be adjusted.
Harmonic compensation rate: >92%
Switching frequency: 12.8kHz
Into the way of line: Top entry
MORE DETAILSGET QUOTE NOWFor more rated voltage range and capacity, welcome to send enquiry for details.
DYNAMIC COMPENSATION HARMONIC
YIY Active Harmonic Filter can realize 2nd to 50th harmonic compensation, and compensation ratio can be set selectively by the customers. Output compensation current follows the system harmonic variation, devoted to green power quality.
Different loads generate variety of harmonic content which changes dynamically during under different working conditions.
GET QUOTE NOWExternal CT detect the load current, DSP as CPU has advanced logic control arithmetic, could quickly track the instruction current, divides the load current into active power and reactive power by using the intelligent FFT, and calculates the harmonic content rapidly and accurately.
Then sends PWM signal to internal IGBT's driver board to control IGBT on and off at 20KHZ frequency.
Finally generates opposite phase compensation current on inverter induction, at the same time CT also detects the output current and negative feedback goes to DSP.
Then DSP proceeds the next logical control to achieve more accurate and stable system.
GET QUOTE NOWInstantaneous Dynamic Response
Is derived from IGBT high frequency converter switching at 16KHz using advanced control techniques.
Parallel working
Enables the YIY-AHF series to be added at later stage in parallel to meet increasing demand. Parallel of different ratings is also possible.
Superior Current-limit Capability
AHF will continue to operate at full compensating mode without shutdown or malfunction in the event of additional loads being added. No overload risk on the existing Active Harmonic Filters will occur. Furthermore harmonic resonance risk is absent.
Power Factor Correction
Enables the YIY-AHF series to be added at later stage in parallel to meet increasing demand. Parallel of different ratings is also possible.
Capacity Ratings
It may increase the maximum capacity up to 1500A by using parallel technology. 3 and 4 wires versions are available and compensation capability ranges from 2rd till 50th harmonic order.
Modular Design
Compact design, wall and rack mount installation, easy to use in new or upgrade exiting switch room Module structure with highest reliability of system 3P4W and 3P3W adapted by same modules, same harmonic mitigation capability.
SVG ( STATIC VAR GENERATOR )
Static var generators (SVG), also known as active power factor compensators (APFC) or instantaneous stepless reactive power compensators, are the ultimate answer to power quality problems caused by low power factor and reactive power demand for a wide range of segments and applications.
TYPE: 220V/ 400V / 500V/ 690V
YIY - SVG Technical Specifications
Max neutral wire current: 30KVAR/50KVAR/ 75KVAR/100KVAR
Reactive power compensation rate: >95%
Switching frequency: 16 kHz
Installation: Rack/wall hanging
Into the way of line: Back entry (rack type), top entry (wall-mounted)
MORE DETAILSGET QUOTE NOWFor more rated voltage range and capacity, welcome to send enquiry for details.
SVG OPERATING PRINCIPLE
The principle of the SVG is very similar to that of Active Power Filter, When the load is generating inductive or capacitive current, it makes load current lagging or leading the voltage.
SVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which means fundamental power factor is unit. YIY-SVG is also capable of correcting load imbalance.
GET QUOTE NOWHigh Frequency Inductor
IGBT
DSP ( Digital Signal Processor )
Fast Response
Smart calculation capability provides fast analysis and response (cycle response time < 20 ms and dynamic response time < 500 ps).
High Operation Efficiency and Low Power Loss
Adopts the latest IGBT for high efficiency of more than 96% and low power consumption.
High Reliability and Safety
Robust design for power systems eliminates resonance problems and harmonic current / voltage amplification extending component life cycles and protecting the system.
Continuous Correction
Step less control. SVG controls from 0 - rated kVAr as one continuous range. Think of it like a power factor “VSD".
Modular Design for Easy Maintenance
- No need for a huge amount of reactors and capacitors maintenance, saving installation space by 20-30%.
- Modular design allows easy maintenance.
- Special ventilation path avoids interference among modules and facilitates assembly with other products.
Low Switch Ripple Output
YIY - SVG uses two identical three-phase full-bridge inverters in parallel to improve equipment capacity, At the same time, IGBT drive adopts PWM switch ripple cancellation technology, which greatly reduces the output ripple.
WHY CHOOSE
GET QUOTE NOWGET QUOTE NOWSVG ( STATIC VAR GENERATOR )
Static var generators (SVG), also known as active power factor compensators (APFC) or instantaneous stepless reactive power compensators, are the ultimate answer to power quality problems caused by low power factor and reactive power demand for a wide range of segments and applications.
AHF ( ACTIVE HARMONIC FILTER )
Active harmonic filters (AHF) are the ultimate answer to power quality problems caused by waveform distortions, low power factor, voltage variations, voltage fluctuations and load unbalance for a wide range of segments and applications.
GET QUOTE NOWGET YOUR FREE QUOTE NOW
Long-term Cooperation Discounts
NEED HELP ?
GET QUOTE NOWYIYEN Electric Technology Co., Ltd.
Tel: +86-13588942900
Whatsapp: +86-13588942900
Email: sales@yiyen.com
Add: 4th Floor, No.281, Wei 18 Road, Economic Development Zone, Yueqing City, 325600, Zhejiang Province, China
Inquiry NowGET QUOTE NOWAVC ( ACTIVE VOLTAGE CONDITIONER )
The YIY-AVC is an inverter based system that protects sensitive industrial and commercial loads from voltage disturbances. Providing fast, accurate voltage sag and surge correction as well as continuous voltage regulation and load voltage compensation. The YIY-AVC has been optimally designed to provide equipment immunity from power quality events on the supply network.
SVG ( STATIC VAR GENERATOR )
Static var generators (SVG), also known as active power factor compensators (APFC) or instantaneous stepless reactive power compensators, are the ultimate answer to power quality problems caused by low power factor and reactive power demand for a wide range of segments and applications.
Power Capcity: Single Phase : 10KVA-1800KVA, Three Phase : 30KVA -3600KVA
YIY - AVC Technical Specifications
Output voltage: To match nominal input voltage
Control model: Independent control on each phase
Overload Capacrty from 100% supply Volte: 150% for 21S, once every 500s
Efficiency: Typically > 95%
Voltage Regulation Accuracy: <±0.5% typical, ±2% max
Capacity: 100% of model rating (kVA)
Display: 7inch Touch Screen (Parameter control, power info, display, fault log, etc.)
Operating Altitude: < 1000 mo fw 5it0h°o Cut derating
MORE DETAILSGET QUOTE NOWFor more rated voltage range and capacity, welcome to send enquiry for details.
AVC WORKING PRINCIPLE
The YIY-AVC consists of two converters that are not on the current path between the load and the utility. Instead, the corrective voltage injection is achieved by means of a transformer winding between the utility and the sensitive load. This configuration results in a very efficient and effective method to provide voltage correction with reduced risk of negative impacts on the load.
The YIY-AVC requires no batteries as it draws the additional energy required during sag to make up the correction voltage from the utility supply. With no ongoing maintenance costs typically associated with batteries the cost of ownership for YIY-AVC systems is very small.
Furthermore, the YIY-AVC contains a redundant internal bypass system that, in the event of overload or internal fault condition, ensures that the load is continued to be supplied from the utility.
GET QUOTE NOWAVC OPERATING DETAILS
GET QUOTE NOWYour Trustworthy Power Quality Solution Provider
AHF ( Active Harmonic Filter )
SVG ( Static Var Generator )
GET FREE QUOTEAVC ( Active Voltage Conditioner )
AHF ( ACTIVE HARMONIC FILTER )
DYNAMIC COMPENSATION HARMONIC
SVG ( STATIC VAR GENERATOR )
AVC ( ACTIVE VOLTAGE CONDITIONER )
Promotion of National Certification
Environmental Protection Concept
WHY CHOOSE
GET QUOTE NOW